Pediatrics & Neonatology
Volume 49, Issue 6 , Pages 234-239 , December 2008

A Follow-up Study of Neonatal Interatrial Shunt with Echocardiography until Twelve to Fifteen Months of Age

  • Chi-Lin Ho

      Affiliations

    • Department of Pediatrics, Cheng-Ching Hospital, Taichung, Taiwan
    • Division of Cardiology, Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan
  • ,
  • Sheng-Ling Jan

      Affiliations

    • Division of Cardiology, Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan
    • Institute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan
    • Corresponding Author InformationCorresponding author. Department of Pediatrics, Taichung Veterans General Hospital, 160 Section 3, Chung-Kang Road, Taichung 40705, Taiwan
  • ,
  • Ming-Chih Lin

      Affiliations

    • Division of Cardiology, Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan
  • ,
  • Yun-Ching Fu

      Affiliations

    • Division of Cardiology, Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan
    • Institute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan

Received 20 May 2008 ,Revised 7 July 2008 ,Accepted 19 September 2008.

References 

  1. Shiraishi H , Ichihashi K , Kuramatsu T , et al.   Left-to-right shunt via the foramen ovale in the early neonatal period: evaluation by Doppler color flow mapping . J Cardiol . 1987;17:559–566
  2. Fukazawa M , Fukushige J , Ueda K . Atrial septal defects in neonates with reference to spontaneous closure . Am Heart J . 1988;116:123–127
  3. Hannu H , Pentti K , Henrik E , et al.   Patency of foramen ovale: does it influence haemodynamics in newborn infants? . Early Hum Dev . 1989;20:281–287
  4. Hiraishi S , Agata Y , Saito K , et al.   Interatrial shunt flow profiles in newborn infants: a colour flow and pulsed Doppler echocardiographic study . Br Heart J . 1991;65:41–45
  5. Markhorst DG , Rothuis E , Sobotka-Plojhar M , et al.   Transient foramen ovale incompetence in the normal newborn: an echocardiographic study . Eur J Pediatr . 1995;154:667–671
  6. Senocak F , Karademir S , Cabuk F , et al.   Spontaneous closure of interatrial septal openings in infants: an echocardiographic study . Int J Cardiol . 1996;53:221–226
  7. Hansen LK , Oxhoj H . High prevalence of interatrial communications during the first three months of life . Pediatr Cardiol . 1997;18:83–85
  8. Connuck D , Sun JP , Super DM , et al.   Incidence of patent ductus arteriosus and patent foramen ovale in normal infants . Am J Cardiol . 2002;89:244–247
  9. Guntheroth WG , Schwaegler R , Trent E . Comparative roles of the atrial septal aneurysm versus patent foramen ovale in systemic embolization with inferences from neonatal studies . Am J Cardiol . 2004;94:1341–1343
  10. Ozcelik N , Atalay S , Tutar E , et al.   The prevalence of interatrial septal openings in newborns and predictive factors for spontaneous closure . Int J Cardiol . 2006;108:207–211
  11. Radzik D , Davignon A , van Doesburg N , et al.   Predictive factors for spontaneous closure of atrial septal defects diagnosed in the first 3 months of life . J Am Coll Cardiol . 1993;22:851–853
  12. Lev M , Arcilla R , Rimoldi HJ , et al.   Premature narrowing or closure of the foramen ovale . Am Heart J . 1963;65:638–647
  13. Hanslik A , Pospisil U , Salzer-Muhar U , et al.   Predictors of spontaneous closure of isolated secundum atrial septal defect in children: a longitudinal study . Pediatrics . 2006;118:1560–1565
  14. Wang N-K , Shen C-T , Lin M-S . Results of echocardiographic screening in 10,000 newborns . Acta Paediatr Tw . 2007;48:7–9
  15. Fisher DC , Fisher EA , Budd JH , et al.   The incidence of patent foramen ovale in 1,000 consecutive patients: a contrast transesophageal echocardiography study . Chest . 1995;107:1504–1509
  16. Meier B , Lock JE . Contemporary management of patent foramen ovale . Circulation . 2003;107:5–9
  17. El Said HG , McMahon CJ , Mullins CE , et al.   Patent foramen ovale morphology and impact on percutaneous device closure . Pediatr Cardiol . 2005;26:62–65
  18. Hagen PT , Scholz DG , Edwards WD . Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts . Mayo Clin Proc . 1984;59:17–20
  19. Cayler GG . Spontaneous functional closure of symptomatic atrial septal defects . N Engl J Med . 1967;276:65–73
  20. Cockerham JT , Martin TC , Gutierrez FR , et al.   Spontaneous closure of secundum atrial septal defect in infants and young children . Am J Cardiol . 1983;52:1267–1271
  21. Sherman FS , Sahn DJ , Valdes-Cruz LM , et al.   Two-dimensional Doppler color flow mapping for detecting atrial and ventricular septal defects: studies in an animal model and in the clinical setting . Herz . 1987;12:212–216
  22. Oberhoffer R , Lang D . Diagnostic criteria of interatrial defects: a single gate pulsed Doppler echocardiographic study . Int J Cardiol . 1989;25:167–171
  23. Riggs T , Sharp SE , Batton D , et al.   Spontaneous closure of atrial septal defects in premature vs. full-term neonates . Pediatr Cardiol . 2000;21:129–134

PII: S1875-9572(09)60017-6

doi: 10.1016/S1875-9572(09)60017-6

Pediatrics & Neonatology
Volume 49, Issue 6 , Pages 234-239 , December 2008